The Invertec® V205-T PULSE is manufactured in a lightweight but robust outer casing, making it portable and ideal for operation, even in the most hazardous environments. The smart switching 230/400V single phase and generator compatibility of the V205-T PULSE allow it. INVERTEC V205-T AC/DC TIG. MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly, think before you act and be careful. V20 5-C/DC For use with machines having Code Numbers: 10860. From the Lincoln Electric Company. Invertec, V205-t ac/dc, For tig and stick welding. Read online or download PDF. Lincoln Electric V205-T AC/DC User Manual.
Advertising
TIME-DELAY CIRCUIT BREAKER
OR FUSE SIZE (AMPS)
30A
A-2
A-2
V205-T AC/DC
INSTALLATION
Input Amps
34A
28A
20A
28A
20A
34A
25A
20A
25A
20A
30A
23A
19A
23A
19A
30A
18A
15A
18A
15A
Type of Output
AC/DC
Output Amps Volts at Rated Amperes
(Stick) 110
24.4V
90
23.6V
70
22.8V
(TIG) 150
16V
120
14.8V
100
14V
(Stick) 180
27.2V
150
26V
130
25.2V
(TIG) 200
18V
170
16V
140
15.6V
Maximum Open
Circuit Voltage
54 Volts Max.
Input Voltages / 50 /60 Hz.
115
230
Duty Cycle
(115V) 35%
60%
100%
100%
(115V) 40%
60%
100%
(230V) 35%
60%
100%
(230V) 40%
60%
100%
Output Current
Range
6-200 Amps
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Height
Width
Depth
Weight
15 in.
8.5 in.
19 in.
Approx. 38 lbs.
Lincoln Invertec 275s Welder Reviews
381 mm
216 mm
483 mm
17 kgs.
PHYSICAL DIMENSIONS
TECHNICAL SPECIFICATIONS - V205-T AC/DC TIG K1855-1 (Code Number 10860)
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-20°C to +40°C
STORAGE TEMPERATURE RANGE
Lincoln Invertec 160
-50°C to +85°C
INPUT
VOLTAGE /
Lincoln 205t Invertec
FREQUENCY
(HZ)
115/50/60
230/50/60
TYPE S, SO ST, STO, OR EXTRA
HARD USAGE INPUT CORD AWG
#12
Max. Input Current
34A at Rated Output
30A at Rated Output
30A at Rated Output
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT